By Brands

Brands

  • Filter

Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032

Current Range: 100mA to 1000 Arms Basic Accuracy 48Hz to 65Hz: 10A Range +/- 3% of reading + 0.1A, 100mV/A output 100A Range +/- 2% of reading + 0.5A, 10mV/A output 1000A Range +/- 1% of reading + 1A, 1mV/A output Bandwidth: 5Hz to 100kHz Working Voltage: 600V AC rms Maximum Conductor Size: 54 mm (2.13 inch) diameter Safety Rating: 600V rms. CAT III per IEC 1010-02-032

Current Range: 1 to 600 A DC or AC Peak Basic Accuracy (DC to 400 Hz): +/- (2% of reading + 1 A) Output Signal: 100 A range: 10 mV/A | 600 A range: 1 mV/A Frequency Range: 40 Hz to 400 Hz Working Voltage: 600 V AC rms Maximum Conductor Diameter: 34 mm (1.34 inch) Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Current Range: 0.1 to 100A DC or 0.1 to 70A AC Basic Accuracy (DC to 1kHz): 100mV/A setting: 50mA to 10A +/- 3% of reading + 50mA 10mV/A setting: 50mA to 40A +/- 4% of reading + 50mA40A to 80A +/- 12% of reading + 50mA80 to 100A +/- 15% of reading Output Signal: 10A range: 100mV/A | 100A range: 10mV/A Bandwidth: 1Hz to 20kHz Working Voltage: 600V AC rms Maximum Conductor Size: 1.8 mm (.46 inch) diameter Safety Rating: IEC 1010 and CSA-C22.2 No. 1010-1 Installation Category II, Working Voltage 600V

Category: Fiber Optics

A variety of light sources allow you to test different cable lengths. One year warranty

Category: Fiber Optics

A variety of light sources allow you to test different cable lengths. One year warranty

Category: Fiber Optics

The compact FOM plugs into your DMM and makes testing in tight spaces easy A variety of light sources (FOS 850, FOS 1300, and FOS 850/1300) and patch cords (ST to ST, ST to FC, ST to SC, ST to SMA) let you get just what you need for testing different cable types and lengths Highly accurate readings mean less work, less repeated testing Input connector: fixed ST Battery life: 16 hours minimum, 9V alkaline LED low battery indicator Operating temperature: 0°C to +40°C (32°F to +104°F) Storage temperature: -20°C to +70°C (-4°F to +158°F)

The CO-205 accessory kit includes: Stainless steel sampling tube Industrial-grade hand operated aspirator to draw flue sample Easy to replace particulate filter Specially designed nose cap for connection to the Fluke CO-210/220 4' (1.2m) hose length